1

For a 7.46 kW, 200 V dc shunt motor with full load efficiency of 85% has armature resistance of 0.25 ohms. Calculate the value of starting resistance in ohms for a current 1.5 times of the full load current.

Correct Answer: 2.788

Make the most of this question

This page focuses on one Electrical Drives and Controls (EDC) question from Engineering. After checking the answer, return to the topic list to practice more or run a timed set.

Electrical Drives and Controls (EDC) MCQ: For a 7.46 kW, 200 V dc shunt motor with full load efficiency of 85% has armature resistance of 0.25 ohms. Calculate the value of starting resistance in ohms for a current 1.5 times of the full load current. | Extra Education