1

A 7.6 cm (3 inches) thick test specimen is radiographed with a source having size of 1.3 cm (1/2 inch), the film is placed in contact with the test specimen. The source to film distance is 40.6 cm (16 inches).The geometric unsharpness obtained is:

Correct Answer: 0.3 cm

Make the most of this question

This page focuses on one Non Destructive Testing and Evaluation question from Engineering. After checking the answer, return to the topic list to practice more or run a timed set.

Non Destructive Testing and Evaluation MCQ: A 7.6 cm (3 inches) thick test specimen is radiographed with a source having size of 1.3 cm (1/2 inch), the film is placed in contact with the test specimen. The source to film distance is 40.6 cm (16 inches).The geometric unsharpness obtained is: | Extra Education