1

A good Cobalt-60 shot is made on a 7.6 cm (3 inches) steel casting using an exposure time of 10 minutes and a source-to-film distance of 91.5 (36 inches). If it is necessary to change the source-to-film distance to 61 cm (24 inches), what exposure time would produce a similar radiograph if all other conditions remain the same?

Correct Answer: 4.4 minutes

Make the most of this question

This page focuses on one Non Destructive Testing and Evaluation question from Engineering. After checking the answer, return to the topic list to practice more or run a timed set.

Non Destructive Testing and Evaluation MCQ: A good Cobalt-60 shot is made on a 7.6 cm (3 inches) steel casting using an exposure time of 10 minutes and a source-to-film distance of 91.5 (36 inches). If it is necessary to change the source-to-film distance to 61 cm (24 inches), what exposure time would produce a similar radiograph if all other conditions remain the same? | Extra Education